Washable Interior Latex Paint
A washable interior wall finish for residential and commercial spaces.
| Application | Interior walls |
Before specifying
Discuss the room use, substrate, color, finish and cleaning requirements.
Confirm the substrate, exposure conditions, coating system and current product documents before specifying a product.
Technical data
| Property | Value | Test method / conditions | Document basis |
|---|---|---|---|
| VOC | 92 g/L | GB 18582-2008 (as printed in the report); no US EPA 24 claim | BETC-HJ-2024-D-00258 / 2024-05-27 |
| Free formaldehyde | 21 mg/kg | GB 18582-2008 (as printed in the report); no US EPA 24 claim | BETC-HJ-2024-D-00258 / 2024-05-27 |
| Soluble lead | 5 mg/kg | GB 18582-2008 (as printed in the report); no US EPA 24 claim | BETC-HJ-2024-D-00258 / 2024-05-27 |
| Sum of benzene, toluene, ethylbenzene and xylenes | Not detected (limit 50 mg/kg) | GB 18582-2008 (as printed in the report); no US EPA 24 claim | BETC-HJ-2024-D-00258 / 2024-05-27 |
| Soluble cadmium, chromium and mercury | Not detected | GB 18582-2008 (as printed in the report); no US EPA 24 claim | BETC-HJ-2024-D-00258 / 2024-05-27 |
Original reports may show the manufacturer's other brand name. The company confirms that the corresponding ARCHORA products use the same formulation and specifications.
Manufacturer's manual data is not an independent test report. Reported results apply to the submitted sample and stated test conditions; they do not establish performance on every job site or constitute international certification.
Application & system
| Property | Value | Test method / conditions | Document basis |
|---|---|---|---|
| Theoretical coverage | Approximately 12 m²/L/coat | Source document | Manual V2 2026-07-09 |
| Recommended coats | 1–2 coats | Source document | Manual V2 2026-07-09 |
| Application method | Roller or airless spray | Source document | Manual V2 2026-07-09 |
| Minimum application temperature | 10 °C | Source document | Manual V2 2026-07-09 |
| Maximum relative humidity | 80 % | Source document | Manual V2 2026-07-09 |
| Recoat interval | ≥2 h at 25°C | Source document | Manual V2 2026-07-09 |
| Cure before heavy cleaning | 14 days | Source document | Manual V2 2026-07-09 |
Confirm the full system for the substrate and project conditions. A protective topcoat is not required for every product.
Documents
Product bulletin / TDS
Product properties, uses, application conditions and storage instructions.
Safety data sheet (SDS)
Hazards, handling, protective measures and other safety information.
Test report
Results for the submitted sample under the stated test conditions.
Website data summary; not a formally issued TDS.