+86 138 8989 9165soniaw@126.comJournalWhite papers & resources
ARCHORABuilding with Confidence, Protecting the Future.
Washable Interior Latex Paint
Application illustration

Washable Interior Latex Paint

A washable interior wall finish for residential and commercial spaces.

ApplicationInterior walls

Before specifying

Discuss the room use, substrate, color, finish and cleaning requirements.

Confirm the substrate, exposure conditions, coating system and current product documents before specifying a product.

Technical data

PropertyValueTest method / conditionsDocument basis
VOC92 g/LGB 18582-2008 (as printed in the report); no US EPA 24 claimBETC-HJ-2024-D-00258 / 2024-05-27
Free formaldehyde21 mg/kgGB 18582-2008 (as printed in the report); no US EPA 24 claimBETC-HJ-2024-D-00258 / 2024-05-27
Soluble lead5 mg/kgGB 18582-2008 (as printed in the report); no US EPA 24 claimBETC-HJ-2024-D-00258 / 2024-05-27
Sum of benzene, toluene, ethylbenzene and xylenesNot detected (limit 50 mg/kg)GB 18582-2008 (as printed in the report); no US EPA 24 claimBETC-HJ-2024-D-00258 / 2024-05-27
Soluble cadmium, chromium and mercuryNot detectedGB 18582-2008 (as printed in the report); no US EPA 24 claimBETC-HJ-2024-D-00258 / 2024-05-27

Original reports may show the manufacturer's other brand name. The company confirms that the corresponding ARCHORA products use the same formulation and specifications.

Manufacturer's manual data is not an independent test report. Reported results apply to the submitted sample and stated test conditions; they do not establish performance on every job site or constitute international certification.

Application & system

PropertyValueTest method / conditionsDocument basis
Theoretical coverageApproximately 12 m²/L/coatSource documentManual V2 2026-07-09
Recommended coats1–2 coatsSource documentManual V2 2026-07-09
Application methodRoller or airless spraySource documentManual V2 2026-07-09
Minimum application temperature10 °CSource documentManual V2 2026-07-09
Maximum relative humidity80 %Source documentManual V2 2026-07-09
Recoat interval≥2 h at 25°CSource documentManual V2 2026-07-09
Cure before heavy cleaning14 daysSource documentManual V2 2026-07-09

Confirm the full system for the substrate and project conditions. A protective topcoat is not required for every product.

Coating systems

Documents

Product bulletin / TDS

Product properties, uses, application conditions and storage instructions.

Safety data sheet (SDS)

Hazards, handling, protective measures and other safety information.

Test report

Results for the submitted sample under the stated test conditions.

Download data summary (CSV)

Website data summary; not a formally issued TDS.

Contact us to confirm the latest TDS and any data not listed here.