Technical data

PropertyValueTest method / conditionsDocument basis
Surface-dry time1 hGB/T 9755-2014BETC-HJ-2024-P-00256 / 2024-05-26
Contrast ratio (white and light colours)0.92GB/T 9755-2014BETC-HJ-2024-P-00256 / 2024-05-26
Dirt pick-up resistance (white and light colours)8 %GB/T 9755-2014BETC-HJ-2024-P-00256 / 2024-05-26
Scrub resistanceNo damage after 2000 cyclesGB/T 9755-2014BETC-HJ-2024-P-00256 / 2024-05-26
Alkali resistanceNo abnormality after 48 hGB/T 9755-2014BETC-HJ-2024-P-00256 / 2024-05-26
Water resistanceNo abnormality after 96 hGB/T 9755-2014BETC-HJ-2024-P-00256 / 2024-05-26
Water permeability0.8 mLGB/T 9755-2014BETC-HJ-2024-P-00256 / 2024-05-26
Artificial weathering400 h; no blistering, peeling or cracking; chalking 0, colour change 0GB/T 9755-2014BETC-HJ-2024-P-00256 / 2024-05-26

Original reports may show the manufacturer's other brand name. The company confirms that the corresponding ARCHORA products use the same formulation and specifications.

Manufacturer's manual data is not an independent test report. Reported results apply to the submitted sample and stated test conditions; they do not establish performance on every job site or constitute international certification.

Application & system

PropertyValueTest method / conditionsDocument basis
Theoretical coverage / consumptionApproximately 11 m²/L/coatSource documentManual V3 2026-07-09
Recommended coats2 coatsSource documentManual V3 2026-07-09
Application methodRoller or airless spraySource documentManual V3 2026-07-09
Application temperature5–35 °CSource documentManual V3 2026-07-09
Relative humidity≤85 %Source documentManual V3 2026-07-09
Recoat / clear-coat interval≥4 h at 25°CSource documentManual V3 2026-07-09

Confirm the full system for the substrate and project conditions. A protective topcoat is not required for every product.

Coating systems

Documents

Product bulletin / TDS

Product properties, uses, application conditions and storage instructions.

Safety data sheet (SDS)

Hazards, handling, protective measures and other safety information.

Test report

Results for the submitted sample under the stated test conditions.

Download data summary (CSV)

Website data summary; not a formally issued TDS.

Contact us to confirm the latest TDS and any data not listed here.